邀好友领红包

标准物质一站式采购平台

下载证书

金标准溶液原子吸收

1000ug/mL GOLD 500mL
  • 价格: ¥1364
  • 编号:AAAU1-5
  • 形态:液体
  • 基质:HCl
  • 货   期:一周
  • CAS号:7440-57-5
  • 品   牌:中国
规格:
  • 500mL, 1000ppm
查看证书 基本信息 相关产品

1.0 ACCREDITATION / REGISTRATION

INORGANIC VENTURES is accredited to ISO Guide 34, "General Requirements for the Competence of Reference Material Producers" and ISO/IEC 17025, "General Requirements for the Competence of Testing and Calibration Laboratories". Inorganic Ventures is also an ISO 9001 registered manufacturer (SAI Global File Number 010105).

2.0 PRODUCT DESC RIPTION

Product Code: Single Analyte Atomic Absorption Solution

Catalog Number:AAAU1

Matrix:10% (v/v) HCI

Value 1 Analyte(s):1 000 μg/mL ea:Gold

3.0 CERTIFIED VALUES AND UNC ERTAINTIES

Certified Value:1000土10 μg/mL

Certified Density:1.019 g/mL (measured at 20±1 °C)

4.0 TRACEABILITY TO NIST

The concentration of this solution standard has been venified by Inductively Coupled Plasma Spectroscopy (ICP) and is traceable to NIST SRM 3121

4.1 Thermometer Calibration

- All thermometers are NIST traceable through themometers that are calibrated by an accredited calibration laboratory.

4.2 Balance Calibration

- All analytical balances are calibrated by an accredited calibration laboratory and procedure. The weights used for testing are annually compared to master weights and are traceable to NIST.

4.3 Glassware Calibration

- An in-house procedure is used to calibrate all Class A glassware used in the manufacturing and quality control of CRM/RMs.

5.0 TRACE METALLIC IMPURITIES (TMI ) DETERMINED BY ICP-MS AND ICP-OES (ug/mL)

N/A

6.0 INTENDED USE

.- For the calibration of analytical instruments and validation of analytical methods as appropriate.

7.0 INSTRUCTIONS FOR THE CORRECT USE OF THIS REFERENCE MATERIAL

7.1 Storage and Handling Recommendations

- Store between approximately 4° - 30℃ while in sealed TCT bag.

- While stored in the sealed TCT bag, transpiration of this CRM/RM is negligible. After opening the sealed TCT bag transpiration of the CRM/RM will occur, resulting in a gradual increase in the analyte concentration(s). It is the responsibility of the user to account for this effect. When the bottle is weighed both before and after being placed in storage, the mass difference observed will be a measure of transpiration mass loss.

. After opening the sealed TCT bag keep cap tightly sealed when not in use. Store and use at 20°土4°℃. Do not pippette from the container. Do not return removed aliquots to container.

- For more information, visit

Atomic Weight; Valence; Coordination Number; Chemical Form in Solution - 196.97 +3 6 Au(CI)63 Chemical Compatibility -Stable in HCI, and HNO3, as the chloride complex. Avoid basic media. Stable with most metals and inorganic anions in acidic media.

Stability - 2-100 ppb levels. 2-10 ppb Au is stable for #1day maximum in 1% HNO3 / LDPE container. 100 ppb is stable for #2 days maximum in 1% HNO3 / LDPE container.1-10,000 ppm solutions chemically stable for years in 10% HCI 1 LDPE container.

Au Containing Samples (Preparation and Solution) - Metal (Aqua Regia ); Oxides ( Soluble in HCI ); Ores (Dissolve in HCI / HNO3).

Atomic Spectroscopic Information (ICP-OES D.L.s are given as radial/axial View):

Technique/Line Estimated D.L. Order Interferences (underlined indicates severe)
ICP-MS 197 amu 5 ppt N/A 181Ta 160
ICP-OES 208.209 nm 0.04/0.01 ug/mL 1 Ir, Re
ICP-OES 242.795 nm 0.02/0.003 μg/mL 1 Mn, Os, Th, Ta, Pt,Co, F
ICP-OES 267.595 nm 0.03/0.003 ug/mL 1 Nb, Ta,U, Cr, Th,Rh, Ru

8.0 HAZARDOUS INFORMATION

- Please refer to the Safety Data Sheet for information regarding this CRM/RM.

9.0 HOMOGENEITY

- This solution was mixed according to an in-house procedure and is guaranteed to be homogeneous. Homogeneity data indicate that the end user should take a minimum sample size of 0.2 mL to assure homogeneity.

10.0 QUALITY STANDARD DOCUMENTATION

10.1 10CFR50 Appendix B - Nuclear Regulatory Commission

Domestic Licensing of Production and Utilization Facilities

10.2 10CFR21 - Nuclear Regulatory Commission

- Reporting defects and Non-Compliance

10.3 ISO 9001 Quality Management System Registration

- SAI Global File Number 010105

11.0 CERTIFICATION, LOT EXPIRATION AND PERIOD OF VALIDITY

11.1 Certification Issue Date

January 26, 2016

- The certification is valid within the measurement uncertainty specified provided the CRM/RM is stored and handled in accordance with instructions given in Sec 7.1. This certification is nulified if instructions in Sec 7.1 are not followed or if the CRM/RM is damaged, contaminated, or otherwise modified.

11.2 Lot Expiration Date

- January 26, 2020

- The date after which this CRM/RM should not be used.

- The lot expiration date reflects the period of time that the stability of a CRM/RM can be supported by long term stability studies conducted on properly stored and handled CRM/RMs. Lot expiration is limited primarily by transpiration (loss of water from the solution) and infrequently by chemical stability.

11.3 Period of Validity

. Sealed TCT Bag Open Date:

- This CRM/RM should not be used longer than one year from the date of removal from the aluminized bag or afer the date given in Sec.11 .2, whichever comes first. This is contingent upon the CRM/RM being handled and stored in accordance with the instructions given in Sec 7.1.

注:以上信息仅供参考,以产品附带证书为准。

金标准溶液原子吸收基本信息
基质 HCl
形态 液体
别名 金标准溶液
标准物质销售提示
关于产品 所有GBW、GSB开头的标准物质,均提供“国家标准物质证书”。因产品种类繁多,北纳标物网上架的只是部分产品,详情请咨询在线客服。
关于技术 北纳标物网客服工作日8:30--18:00在线,欢迎随时咨询标准物质价格、标准物质证书、标准物质检测检验等相关信息。
关于发票 北纳标物网可自助申请开具发票,订单金额累计满5000元以上可开具增值税专用发票。
关于发货 北纳标物网拥有成熟完善的标准物质供应链,当日发货率达80%以上。
关于验收 买方收到产品后请立即对标准物质数量、规格型号、包装等进行标准验收。若有问题请在收到货3天内联系客服,未提出任何异议,则视为收讫。
相关产品
热门产品
关于 金标准溶液原子吸收 我来说两句

登录后才可以评论

立即登录
请告知您的电话号码,我们将立即回电

通话对您免费,请放心接听

温馨提示:

1.手机直接输入,座机前请加区号 如13164239859,010-58103778

2.我们将根据您提供的电话号码,立即回电,请注意接听

3.因为您是被叫方,通话对您免费,请放心接听

关闭
大抽奖
请设置您的密码:
分享到微信